LC

Daikin LC Error Code – Malfunction of Transmission Between Control and Inverter PCB

Air Conditioner · HIGH Severity

HIGH severity Air Conditioner Model: Daikin Inverter 18000 BTU
What This Error Means
Defective connection between inverter PCB and control PCB, external noise or defective inverter compressor
Diagnostic & Repair Steps
1
Check Communication Wire
Inspect the communication cable between indoor and outdoor unit. Look for cuts, pinches, or disconnections. 🔧 Flashlight
INSPECT ~10 min
2
Check Terminal Block Connections
Verify correct wire connections at both indoor and outdoor terminal blocks. Ensure wires are on correct terminals (L, N, 1, 2, 3 or S). 🔧 Screwdriver, multimeter ⚠️ Disconnect power before inspecting terminal connections
CHECK ~10 min
3
Test Communication Signal
Set multimeter to AC Volts. Measure between communication terminals while unit is powered. Should show ~12-24V AC pulsing signal. 🔧 Multimeter
TEST ~15 min
4
Check PCB for Damage
Inspect indoor and outdoor unit PCBs for burnt components, swollen capacitors, or visible physical damage. 🔧 Flashlight ⚠️ Discharge capacitors before handling PCB
INSPECT ~10 min
5
Replace Faulty PCB
If wiring is intact but no signal is present, replace the faulty PCB (usually indoor PCB first, then outdoor). 🔧 Screwdrivers, ESD wrist strap
REPLACE ~30 min

Need professional PCB repair in Colombo?