61

LG 61 Error Code – Outdoor Condenser Coil Temp High

Air Conditioner · CRITICAL Severity

CRITICAL severity Air Conditioner Model: LG LS091HSV Indoor Unit
What This Error Means
Outdoor unit condenser coil temperature is too high
Diagnostic & Repair Steps
1
Check Outdoor Condenser Coil
Inspect for dirt or blockage causing high temperature. 🔧 Flashlight
INSPECT ~10 min
2
Clean Condenser Coil
Clean fins with compressed air or low-pressure water. 🔧 Air compressor ⚠️ No high pressure water
CLEAN ~20 min
3
Check Outdoor Fan
Verify fan is running correctly. 🔧 None
CHECK ~5 min
4
Check Refrigerant Charge
Overcharge causes high condenser temperature. 🔧 Manifold gauge set ⚠️ Certified technician only
TEST ~20 min
5
Refer to LG Service Manual
Visit www.lg-dfs.com for detailed troubleshooting. 🔧 Service manual
CHECK ~10 min