CH60

LG CH60 Error Code – Outdoor unit PCB EEPROM check sum error.

Air Conditioner · CRITICAL Severity

CRITICAL severity Air Conditioner Model: LG LS091HSV Outdoor Unit
What This Error Means
If the PCB tracks are not damaged, replace the outdoor PCB.
Diagnostic & Repair Steps
1
Power Reset
Turn off the unit at the main switch. Wait 10 minutes to allow all capacitors to fully discharge. Restart and observe if the error clears. 🔧 None ⚠️ Wait full 10 minutes - inverter capacitors hold dangerous charge
RESET ~10 min
2
Visual Inspection of PCB
Inspect the outdoor unit PCB/inverter board for burnt components, swollen capacitors, burnt smell, or visible physical damage. 🔧 Flashlight, screwdrivers ⚠️ Discharge capacitors before handling PCB - use discharge resistor
INSPECT ~15 min
3
Check Input Power Supply
Measure incoming power supply voltage at the outdoor unit terminal block. Verify voltage is within acceptable range (220-240V AC ±10%). 🔧 Multimeter (True RMS) ⚠️ Extreme caution when measuring live voltage
TEST ~10 min
4
Check Compressor and Wiring
Inspect compressor UVW wiring connections at the inverter PCB. Ensure connectors are secure and wires are undamaged. Measure compressor winding resistance. 🔧 Multimeter, screwdrivers ⚠️ Ensure capacitors are discharged before working on inverter
CHECK ~15 min
5
Replace Inverter/Control PCB
If no external fault is found, the inverter PCB or control PCB is likely faulty and requires replacement with the correct part number. 🔧 Screwdrivers, ESD wrist strap, insulated tools ⚠️ Ensure power is off and capacitors are fully discharged before replacement
REPLACE ~45 min