E6

Midea E6 Error Code – Room/Evaporator Sensor Error

Air Conditioner · HIGH Severity

HIGH severity Air Conditioner Model: Midea R Series AC
What This Error Means
Open or short circuit of room or evaporator temperature sensor
Diagnostic & Repair Steps
1
Power Reset
Turn off AC at breaker, wait 5 minutes, restart. 🔧 None
RESET ~5 min
2
Locate Room/Evaporator Sensor
Find the thermistor probe near the evaporator coil inside the indoor unit. 🔧 Flashlight, screwdriver
INSPECT ~10 min
3
Check Sensor Connector
Disconnect and reconnect connector. Check for bent pins or corrosion. 🔧 Needle-nose pliers
CHECK ~5 min
4
Measure Sensor Resistance
At 25C should read approximately 10k?. Replace if open or short circuit. 🔧 Multimeter ⚠️ Disconnect power before measuring
TEST ~15 min
5
Replace Sensor
Replace faulty NTC thermistor with correct Midea part. 🔧 Soldering iron or connector
REPLACE ~20 min