ERR-INV

Midea ERR-INV Error Code – Inverter Module Protection

Air Conditioner · CRITICAL Severity

CRITICAL severity Air Conditioner Model: Midea Cassette/Ceiling Floor AC
What This Error Means
Inverter module protection activated
Diagnostic & Repair Steps
1
Power Off Immediately
Switch off at breaker. 🔧 None
RESET ~2 min
2
Inspect Inverter Module
Check for burn marks or damage. 🔧 Flashlight ⚠️ Wait 10 min after power off
INSPECT ~15 min
3
Check Refrigerant Charge
Incorrect charge stresses inverter. 🔧 Manifold gauge set ⚠️ Certified technician only
TEST ~20 min
4
Check Compressor Windings
Measure resistance. 🔧 Multimeter
TEST ~20 min
5
Replace Inverter Module/PCB
Replace faulty component. 🔧 New PCB
REPLACE ~45 min

Need professional PCB repair in Colombo?

Midea ERR-INV errors often require board-level repair. Bottrixx, a trusted electronics repair company in Colombo 02, diagnoses and repairs Air Conditioner PCBs with fast turnaround and same-day service available.