P2

Midea P2 Error Code – Compressor Top Temp Protection

Air Conditioner · CRITICAL Severity

CRITICAL severity Air Conditioner Model: Midea R Series AC
What This Error Means
Temperature protection of compressor top
Diagnostic & Repair Steps
1
Power Off and Allow Cooling
Turn off AC and allow compressor to cool for at least 30 minutes before proceeding. 🔧 None ⚠️ Do not restart while compressor is hot
RESET ~30 min
2
Check Condenser Coil
Inspect outdoor condenser coil for blockage by dirt or debris. 🔧 Flashlight
INSPECT ~10 min
3
Clean Condenser Coil
Clean condenser fins with compressed air or low-pressure water. 🔧 Air compressor, fin comb ⚠️ Do not use high pressure water
CLEAN ~20 min
4
Check Refrigerant Charge
Low refrigerant can cause compressor to overheat. Check system pressures. 🔧 Manifold gauge set ⚠️ Only certified technicians handle refrigerant
TEST ~20 min
5
Check Compressor Discharge Sensor
Test compressor discharge temperature sensor. Replace if faulty. 🔧 Multimeter
TEST ~15 min