P4

Midea P4 Error Code – Inverter Compressor Drive Error

Air Conditioner · CRITICAL Severity

CRITICAL severity Air Conditioner Model: Midea R Series AC
What This Error Means
Inverter compressor drive error
Diagnostic & Repair Steps
1
Power Off Immediately
Switch off AC at breaker. P4 is a compressor drive error. 🔧 None
RESET ~2 min
2
Check Inverter PCB
Inspect outdoor inverter PCB for burn marks, swollen capacitors, or physical damage. 🔧 Flashlight ⚠️ Wait 10 min after power off for capacitors to discharge
INSPECT ~15 min
3
Check Compressor Windings
Measure compressor winding resistance and insulation with multimeter/megger. 🔧 Multimeter, megger ⚠️ Disconnect power before testing
TEST ~20 min
4
Check Wiring Between PCB and Compressor
Inspect UVW wiring harness from inverter PCB to compressor for damage. 🔧 Flashlight
INSPECT ~10 min
5
Replace Inverter PCB or Compressor
Based on findings, replace faulty inverter PCB or compressor. Engage qualified technician. 🔧 New PCB or compressor
REPLACE ~60 min

Need professional PCB repair in Colombo?

Midea P4 errors often require board-level repair. Bottrixx, a trusted electronics repair company in Colombo 02, diagnoses and repairs Air Conditioner PCBs with fast turnaround and same-day service available.