P5
Midea P5 Error Code – Inverter Module Protection
Air Conditioner · CRITICAL Severity
What This Error Means
Inverter module protection activated
Diagnostic & Repair Steps
1
Power Off
Switch off at breaker.
Switch off at breaker.
RESET
~2 min
2
Inspect Inverter Module
Check inverter PCB for physical damage. ⚠️ Disconnect and wait 10 min
Check inverter PCB for physical damage. ⚠️ Disconnect and wait 10 min
INSPECT
~15 min
3
Check Refrigerant
Incorrect charge stresses inverter module. ⚠️ Certified technician only
Incorrect charge stresses inverter module. ⚠️ Certified technician only
TEST
~20 min
4
Check Compressor Windings
Measure compressor resistance.
Measure compressor resistance.
TEST
~20 min
5
Replace Inverter Module/PCB
Replace if confirmed faulty.
Replace if confirmed faulty.
REPLACE
~45 min
Need professional PCB repair in Colombo?
Midea P5 errors often require board-level repair. Bottrixx, a trusted electronics repair company in Colombo 02, diagnoses and repairs Air Conditioner PCBs with fast turnaround and same-day service available.