E06

Panasonic E06 Error Code – High Compressor Discharge Temp

Air Conditioner · CRITICAL Severity

CRITICAL severity Air Conditioner Model: Panasonic Inverter AC (S/E series)
What This Error Means
High compressor discharge temperature
Diagnostic & Repair Steps
1
Power Off Immediately
High discharge temp is critical. 🔧 None
RESET ~2 min
2
Allow System to Cool
Wait 30 minutes. 🔧 None
RESET ~30 min
3
Refer to Detailed Diagnostics
Follow Panasonic diagnostic procedure. 🔧 Service manual
CHECK ~20 min
4
Check Refrigerant Charge
Low charge causes high discharge temp. 🔧 Manifold gauge set ⚠️ Certified technician only
TEST ~20 min
5
Check Compressor Discharge Sensor
Test and replace if faulty. 🔧 Multimeter
TEST ~15 min