ERR-T2

Midea ERR-T2 Error Code – Indoor Pipe Temp Sensor Error

Air Conditioner · HIGH Severity

HIGH severity Air Conditioner Model: Midea Cassette/Ceiling Floor AC
What This Error Means
Indoor pipe temp sensor open or short-circuit
Diagnostic & Repair Steps
1
Power Reset
Turn off at breaker, wait 5 minutes, restart. 🔧 None
RESET ~5 min
2
Locate Indoor Pipe Temp Sensor
Find thermistor clipped to indoor coil pipe. 🔧 Flashlight
INSPECT ~10 min
3
Check Sensor Connector
Reconnect and inspect for corrosion. 🔧 Pliers
CHECK ~5 min
4
Measure Sensor Resistance
Replace if open or short circuit. 🔧 Multimeter ⚠️ Disconnect power first
TEST ~15 min
5
Replace Sensor
Replace faulty NTC thermistor. 🔧 Connector
REPLACE ~20 min