ERR-T3

Midea ERR-T3 Error Code – Outdoor Condenser Sensor Error

Air Conditioner · HIGH Severity

HIGH severity Air Conditioner Model: Midea MSH-21HRN1-QB8
What This Error Means
Temp sensor on outdoor condenser open circuit or short circuit
Diagnostic & Repair Steps
1
Power Reset
Turn off at breaker, wait 5 min, restart. 🔧 None
RESET ~5 min
2
Locate Outdoor Condenser Sensor
Find thermistor on outdoor condenser coil. 🔧 Flashlight
INSPECT ~10 min
3
Check Sensor Connector
Reconnect and inspect. 🔧 Pliers
CHECK ~5 min
4
Measure Resistance
~10k? at 25C expected. 🔧 Multimeter ⚠️ Disconnect power first
TEST ~15 min
5
Replace Sensor
Replace faulty NTC thermistor. 🔧 Connector
REPLACE ~20 min